SFP-GQS-SPO400-LR4CD
The SFP-GQS-SPO400-LR4CD is a 4x10G hot pluggable optical transceiver. The LYCOM technology enables the integration of 4 transmitters, 4 receivers and an optical MUX/DeMUX with AAWG into a small form factor package that delivers a 40 Gbps data link in a compact QSFP footprint. The optical connectivity is based on two SMF LC connectors, one for Tx and one for Rx. The Tx and Rx each consist of 4 10Gb/s CWDM channels, whose wavelengths are in the 1300nm range. The QSFP-LR transceiver is designed for applications based on the QSFP MSA, IEEE 802.3ba, 40GBASE-LR4 and OTU3 C4S1-2D1 requirements specified in ITU-T recommendation G.695 of up to 10km reach.
SFP-GQS-SPO400-LR4CD
Transmission data rate up to 11.2Gbps per channel
QSFP+ MSA compliant
Compliant to IEEE 802.3ba specification for 40GBASE-LR4 links
4 CWDM un-cooled DFB lasers, using ITU G.694.2 wavelength grid at 1271, 1291, 1311, and 1331 nm , with AAWG.
High Sensitivity PIN-TIA with AAWG DEMUX.
Up to 10km reach over standard single mode fiber
Compliant with QDR/DDR Infiniband data rates
Hot pluggable electrical interface
Power consumption<2.5W,3.3V power supply
Operating case temperature 0°C to +70°C
RoHS 6 compliant(lead free)
Pin Descriptions
Pin |
Logic |
Symbol |
Name/Description |
Ref. |
1 |
|
GND |
Module Ground |
1 |
2 |
CML-I |
Tx2- |
Transmitter inverted data input |
|
3 |
CML-I |
Tx2+ |
Transmitter non-inverted data input |
|
4 |
|
GND |
Module Ground |
1 |
5 |
CML-I |
Tx4- |
Transmitter inverted data input |
|
6 |
CML-I |
Tx4+ |
Transmitter non-inverted data input |
|
7 |
|
GND |
Module Ground |
1 |
8 |
LVTTL-I |
MODSEIL |
Module Select |
2 |
9 |
LVTTL-I |
ResetL |
Module Reset |
2 |
10 |
|
VCCRx |
+3.3v Receiver Power Supply |
|
11 |
LVCMOS-I |
SCL |
2-wire Serial interface clock |
2 |
12 |
LVCMOS-I/O |
SDA |
2-wire Serial interface data |
2 |
13 |
|
GND |
Module Ground |
1 |
14 |
CML-O |
RX3+ |
Receiver non-inverted data output |
|
15 |
CML-O |
RX3- |
Receiver inverted data output |
|
16 |
|
GND |
Module Ground |
1 |
17 |
CML-O |
RX1+ |
Receiver non-inverted data output |
|
18 |
CML-O |
RX1- |
Receiver inverted data output |
|
19 |
|
GND |
Module Ground |
1 |
20 |
|
GND |
Module Ground |
1 |
21 |
CML-O |
RX2- |
Receiver inverted data output |
|
22 |
CML-O |
RX2+ |
Receiver non-inverted data output |
|
23 |
|
GND |
Module Ground |
1 |
24 |
CML-O |
RX4- |
Receiver inverted data output |
|
25 |
CML-O |
RX4+ |
Receiver non-inverted data output |
|
26 |
|
GND |
Module Ground |
1 |
27 |
LVTTL-O |
ModPrsL |
Module Present, internal pulled down to GND |
|
28 |
LVTTL-O |
IntL |
Interrupt output, should be pulled up on host board |
2 |
29 |
|
VCCTx |
+3.3v Transmitter Power Supply |
|
30 |
|
VCC1 |
+3.3v Power Supply |
|
31 |
LVTTL-I |
LPMode |
Low Power Mode |
2 |
32 |
|
GND |
Module Ground |
1 |
33 |
CML-I |
Tx3+ |
Transmitter non-inverted data input |
|
34 |
CML-I |
Tx3- |
Transmitter inverted data input |
|
35 |
|
GND |
Module Ground |
1 |
36 |
CML-I |
Tx1+ |
Transmitter non-inverted data input |
|
37 |
CML-I |
Tx1- |
Transmitter inverted data input |
|
38 |
|
GND |
Module Ground |
1 |
Notes:
1. Module circuit ground is isolated from module chassis ground within the module.
2. Open collector; should be pulled up with 4.7k – 10k ohms on host board to a voltage between 3.15V and 3.6V.
Ordering information
Part Number |
Product Description |
SFP-GQS-SPO400-LR4CD |
40Gb/s QSFP+ LR4,Pull-Tab,10 km on a standard single mode fiber
Compliant to OTU3, OTU3e1, OTU3e2 specification |