SFP-GQS-MPO101-SR4C
The LYCOM 100GBASE-SR4 100m QSFP28 optical transceiver, 100G QSFP28 SR4 (SFP-GQS-MPO101-SR4C) is designed for use in 100-Gigabit Ethernet links up to 100m over Multi-Mode Fiber (MMF). It is compliant with the QSFP28 MSA and IEEE 802.3bm 100GBASE-SR4 and CAUI-4. Digital diagnostics functions are available via the I2C interface, as specified by the QSFP28 MSA. It integrates 4 data lanes in each direction with 4×25.78125Gb/s bandwidth. The electrical interface uses a 38-contact edge type connector. The optical interface uses a 12-fiber MTP/MPO connector. This module incorporates LYCOM proven circuit and VCSEL technology to provide reliable long life, high performance, and consistent service.
SFP-GQS-MPO101-SR4C
Hot-pluggable QSFP28 form factor
4 channels full-duplex transceiver module
Supports 103.125Gb/s aggregate bit rate
4 channels 850nm VCSEL array
4 channels PIN photo-detector array
Internal CDR circuits on both receiver and transmitter channels
Supports CDR bypass
2.5W maximum power dissipation
Maximum link length of 70m on OM3 MMF and 100m on OM4 MMF
Single MTP/MPO receptacle
Operating case temperature range: 0 to 70°C
Single 3.3V power supply
RoHS-6 compliant (lead free)
Pin Descriptions
Pin |
Logic |
Symbol |
Name/Description |
1 |
|
GND |
Module Ground1 |
2 |
CML-I |
Tx2- |
Transmitter inverted data input |
3 |
CML-I |
Tx2+ |
Transmitter non-inverted data input |
4 |
|
GND |
Module Ground1 |
5 |
CML-I |
Tx4- |
Transmitter inverted data input |
6 |
CML-I |
Tx4+ |
Transmitter non-inverted data input |
7 |
|
GND |
Module Ground1 |
8 |
LVTTL-I |
MODSEIL |
Module Select2 |
9 |
LVTTL-I |
ResetL |
Module Reset2 |
10 |
|
VCCRx |
+3.3V Receiver Power Supply |
11 |
LVCMOS-I |
SCL |
2-wire Serial interface clock2 |
12 |
LVCMOS-I/O |
SDA |
2-wire Serial interface data2 |
13 |
|
GND |
Module Ground1 |
14 |
CML-O |
RX3+ |
Receiver non-inverted data output |
15 |
CML-O |
RX3- |
Receiver inverted data output |
16 |
|
GND |
Module Ground1 |
17 |
CML-O |
RX1+ |
Receiver non-inverted data output |
18 |
CML-O |
RX1- |
Receiver inverted data output |
19 |
|
GND |
Module Ground1 |
20 |
|
GND |
Module Ground1 |
21 |
CML-O |
RX2- |
Receiver inverted data output |
22 |
CML-O |
RX2+ |
Receiver non-inverted data output |
23 |
|
GND |
Module Ground1 |
24 |
CML-O |
RX4- |
Receiver inverted data output |
25 |
CML-O |
RX4+ |
Receiver non-inverted data output |
26 |
|
GND |
Module Ground1 |
27 |
LVTTL-O |
ModPrsL |
Module Present, internal pulled down to GND |
28 |
LVTTL-O |
IntL |
Interrupt output, should be pulled up on host board2 |
29 |
|
VCCTx |
+3.3V Transmitter Power Supply |
30 |
|
VCC1 |
+3.3V Power Supply |
31 |
LVTTL-I |
LPMode |
Low Power Mode2 |
32 |
|
GND |
Module Ground1 |
33 |
CML-I |
Tx3+ |
Transmitter non-inverted data input |
34 |
CML-I |
Tx3- |
Transmitter inverted data input |
35 |
|
GND |
Module Ground1 |
36 |
CML-I |
Tx1+ |
Transmitter non-inverted data input |
37 |
CML-I |
Tx1- |
Transmitter inverted data input |
38 |
|
GND |
Module Ground1 |
Note:
1. Module circuit ground is isolated from module chassis ground within the module.
2. Open collector should be pulled up with 4.7K to 10K ohms on host board to a voltage between 3.15V and 3.6V.
Ordering Information:
Product Description |
Part Number |
SFP-QSFP28 SR4, 103.125Gb/s, 850nm, 100m, MMF, MTP/MPO |
SFP-GQS-MPO101-SR4C |